[18F] FLOURINE SYNTHRA RN PLUS

Synthra RNplus is a flexible and completely automated radio synthesis system for routine production of wide variety of [18F]fluorine labeled compounds by nucleophilic substitution, with automated sequences for compounds like [18F]F-DOPA, [18F]FDG, [18F]FLT, [18F]FET, [18F]FHBG, [18F]FDDNP, [18F]MISO, [18F]FAZA, [18F]FES and [18F] Fluorocholine. For any other [18F]labeled customer compounds an automated sequence will be generated. The synthesis unit includes all components needed for preparation, labeling, purification and formulation of [18F]fluorine labeled compounds. Automating the synthesis is simple, with the easy-to-use configuration software Synthra View, the Synthra RNplus module offers both, fully automatic and manual modes of operation.
The radio synthesis system has a dedicated sub system for the recovery and collection of [18O]H2O for the purification of the cyclotron produced [18F]fluoride. The target activity is measured with a separated detector.
There are two synthesis reaction vessels and one column oven for a solid support reaction zone, allowing multiple step (homogenous and heterogeneous) synthesis reactions. The reaction vessels include PID controlled heaters for a temperature range between -50 °C and 250 °C. The optimized heating and cooling from 20 °C to 100 °C takes only 1 minute. A collection pipe for the exhausted cooling gas is provided. Each reaction vessel is equipped with a pressure transducer, a temperature sensor and a radioactivity detector.
Flexible and completely automated radio synthesis system Production of wide variety of Fluorine-18 labelled compounds by nucleophilic substitution
- [18F]F-DOPA
- [18F]FDG
- [18F]FLT
- [18F]FHBG
- [18F]FDDNP
- [18F]MISO
- [18F]FAZA
- [18F]Fluorocholin
SYNTHRA RN plus module offers both fully automatic and manual modes of operation.
Technical Description
- Built-in filter integrity test for final filtration
- Built-in preparative Radio/HPLC system for product collection
- Two glassy carbon reaction vessels for homogenous reactions
- Column oven for solid support reactions
- Two pressure transducers to monitor reaction vessel pressure
- Chemically inert valves with low dead volume
- Chemically inert vacuum pump
- 15 glass vials for reagents
- O-18 water recovery capability
- Chemical inert dispenser
- Automatic, pneumatic injection valve
All wetted components are chemical inert
Dimensions and Weight Size (WxDxH) 53 x 50 x 50 cm
Weight Approx. 45 kg
Minimum Hot cell size:- 65 x 50 x 50 cm